Diathermy Active Foot Control Electrosurgical Pencil
Diathermy Active Foot Control Electrosurgical Pencil

Diathermy Active Foot Control Electrosurgical Pencil

Diathermy Active Foot Control Electrosurgical Pencil Specification

  • Application
  • Electrosurgery
  • Properties
  • Ergonomic design for surgical precision
  • Temperature Range
  • 5C to 40C
  • Treatment Type
  • Surgical treatment
  • Shape
  • Straight Pencil
  • Suitable For
  • Diathermy machines
  • Function
  • Electrosurgery cutting and coagulation
  • Height
  • 15cm
  • Use
  • Used for cutting or coagulation in surgeries
  • Product Type
  • Electrosurgical Pencil
  • Color Code
  • Black
  • Phase
  • Single Phase
  • Weight
  • 150 grams
  • Material
  • Plastic and Metal
  • Automation Grade
  • Manual
  • Power
  • 40W
  • Frequency
  • 50Hz
  • Humidity Range
  • 0%-85% RH
  • Power Source
  • Electric
  • Voltage
  • 220V
  • Display
  • None
 
 

About Diathermy Active Foot Control Electrosurgical Pencil

The Diathermy Active Foot Control Electrosurgical Pencil is a medical device used in surgical procedures to cut, coagulate and seal tissue. One of the main reasons to buy this pencil is its active foot control feature, which allows the surgeon to activate the electrosurgical energy with their foot. This frees up the surgeons hands, making it easier to perform precise and controlled cuts during the procedure. Additionally, this Diathermy Active Foot Control Electrosurgical Pencil is designed to be ergonomically friendly, which reduces hand fatigue and strain during long surgeries. The pencil is also reusable, making it a cost-effective and environmentally-friendly option for healthcare facilities.

FAQs of Diathermy Active Foot Control Electrosurgical Pencil:


Q: What is the primary function of the Diathermy Active Foot Control Electrosurgical Pencil?

A: The Diathermy Active Foot Control Electrosurgical Pencil is primarily used for cutting and coagulation during surgical procedures.

Q: What type of power source does this electrosurgical pencil require?

A: The electrosurgical pencil operates on an electric power source with a voltage requirement of 220V.

Q: What is the weight and height of this electrosurgical pencil?

A: The pencil weighs 150 grams and has a height of 15 cm.

Q: What is the suitable operational humidity range for this device?

A: The device can operate in a humidity range of 0% to 85% RH.

Q: Is this pencil compatible with diathermy machines?

A: Yes, this electrosurgical pencil is suitable for use with diathermy machines.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Electro Surgery Accessories Category

Silicon Patient Plate

Silicon Patient Plate

Use : Electrosurgical grounding

Properties : High thermal conductivity durable reusable

Application : Electrosurgical procedures

Suitable For : Medical devices

Shape : Rectangular

Treatment Type : Electrosurgical

Patient Return Electrode, Silicon

Patient Return Electrode, Silicon

Use : To safely return electrical current from the patient to the electrosurgical generator

Properties : Good conductivity reusable

Application : Electrosurgical Procedures

Suitable For : Electrosurgery

Shape : Rectangular with handle extension

Treatment Type : Electrosurgical Treatment

Disposable Pediatric Patient Plate

Disposable Pediatric Patient Plate

Use : Singleuse only

Properties : Disposable Skinfriendly adhesive

Application : Used in medical procedures for pediatric patients

Suitable For : Pediatric Patients

Shape : Rectangular

Treatment Type : Electrosurgical Procedures

Electro Surgery Diathermy Bipolar Forceps For Cautery

Electro Surgery Diathermy Bipolar Forceps For Cautery

Use : Medical Procedures

Properties : Durable nonstick reusable

Application : Cauterization during surgical procedures

Suitable For : Bipolar Electrosurgical Units

Shape : Multiple forceps shapes and sizes

Treatment Type : Electrosurgery



Back to top